Invented here, untestedInformation
The Crypto Sleeve
A small box that sits on the cable of any old controller, meter or ground-station modem and wraps its traffic in quantum-safe encryption, with a root of trust that can change algorithms by signed command, so machines built to last decades never have to be replaced to stay safe.
How it works
Grids, pipelines, water plants and satellite ground links run on controllers that can last more than 20 years and speak protocols such as Modbus, which cannot authenticate a command. Many cannot be patched, and replacing them all by 2030 would mean rebuilding much of the world's infrastructure in four years. A sleeve goes in the wire between the old device and the network and changes neither end. Two sleeves set up a tunnel with hybrid key agreement, X25519 together with ML-KEM-768, so the link stays safe if either one falls, and then protect each message with AES-256, adding about 20 bytes. The new keys are large: an ML-KEM-768 key and ciphertext together are 2,272 bytes, about 1.9 seconds on a 9,600 bit/s serial radio, so sleeves agree a key once per session and refresh it in the background, never per message. A 2,420-byte ML-DSA-44 signature would cost 2 seconds a message on the same link, so commands that must be signed are signed in batches: one signature covers the root of a hash tree over a thousand commands, and each command carries only its 10 hashes along the tree, 320 bytes. The sleeve's firmware and its choice of algorithm are signed with LMS, a hash-based signature whose security rests only on the hash function. If lattice mathematics ever falls, an LMS-signed policy can still switch every sleeve to HQC, which rests on codes instead, with no site visit.
The first experiment
- Goal
- Show that sleeves can protect real legacy control traffic with quantum-safe cryptography without breaking its timing, and change algorithm in the field by signed command.
- Setup
- Twenty sleeves built on a microcontroller with a hardware AES engine and a secure element, in a utility or university grid test bed, fitted to real remote terminal units and programmable logic controllers speaking DNP3 and Modbus, over Ethernet and over 9,600 bit/s serial radio. The control loops run for six months. In the fourth month a single LMS-signed policy, sent from the control room, switches every sleeve from ML-KEM to HQC. A red team with access to the radio and the network tries to read, replay and inject commands throughout.
- Measure
- Latency added to each message on each link; time to set up and refresh sessions; control loops that miss their timing; time and link loss during the algorithm switch; every successful read, replay or injection by the red team.
- Succeeds if
- The sleeves add under 10 ms per message on Ethernet and under 50 ms beyond airtime on serial radio, no control loop misses its timing, all twenty switch algorithm by signed command with under one minute of lost link and no site visit, and the red team reads or injects nothing.
From the bench to civilization scale
- On the bench20 devices, 6 months.Twenty sleeves on real controllers in a grid test bed, with a red team. Proves: Quantum-safe protection fits legacy timing, and algorithms can change in the field.
- PrototypeAbout 300 devices at 2 sites.Sleeves across one substation or water plant and on one satellite ground station's command link, for a year. Proves: Sleeves survive real operations, maintenance and failures without stopping the plant.
- PilotAbout 5,000 devices in 1 utility.A utility's whole control network sleeved, with keys and policies run from its control room. Proves: Operators can run fleet-wide key and algorithm changes as routine work.
- First plantAbout 1 million chips a year.The sleeve shrunk to a certified chip built into new terminal units, meters and modems. Proves: New equipment ships able to change its cryptography for its whole life.
- FleetAbout 100 million devices, before the 2030 deadlines.Grids, pipelines, water systems and satellite links across the world sleeved or rebuilt with the chip. Proves: The move to quantum-safe cryptography does not wait for equipment to wear out.
- Civilization scaleEvery link the industry depends on as it nears 1 PWEvery long-lived machine of the climb, from lunar mines to the swarm's collectors, able to change its cryptography by signed command. Proves: No machine is ever replaced, or left open, because its mathematics aged.
What it builds on
- RFC 4301, the IPsec architecture, which describes bump-in-the-wire implementations, a dedicated inline security processor serving a host or a gateway, common in military systems and some commercial ones. rfc-editor.org, 2005
- NIST SP 800-82r3, the guide to operational technology security, which notes that such systems can last more than 20 years, that many legacy ones cannot be patched, and that many field devices and protocols cannot be authenticated, so data can be replayed, modified or spoofed. nvlpubs.nist.gov, 2023
- FIPS 203's ML-KEM-768, with a 1,184-byte encapsulation key and a 1,088-byte ciphertext. nvlpubs.nist.gov, 2024
- The hybrid key agreement X25519MLKEM768, enabled by default in recent browsers and TLS libraries, which carried most human-initiated traffic through Cloudflare by October 2025. blog.cloudflare.com, 2025
- NIST SP 800-208, which standardises the stateful hash-based signatures LMS and XMSS. csrc.nist.gov, 2020
- HQC, chosen by NIST in 2025 as a backup to ML-KEM because it rests on different mathematics. nist.gov, 2025
- Ed25519, whose 64-byte signatures and 32-byte public keys set the size today's slow links were designed around. rfc-editor.org, 2017
What could go wrong, and what to try next
The fastest protection messages in substations must arrive within a few milliseconds and may not tolerate even a sleeve's delay; the next try is an authentication-only mode with hardware hashing for those messages. Cryptographic code on small chips can leak keys through power and timing; masked implementations and certification testing come before any field trial. Stateful hash signatures fail if a key state is ever reused; the root key lives in a hardware module at the operator that counts every signature, with a second, independent root held in reserve. Operators may refuse inline devices on safety grounds; each sleeve has a bypass that only the operator can switch.