Water · needed from Abundance on Earth (2071)
Desalination near the energy floor
Taking the salt out of seawater has a floor set by thermodynamics: 1.06 kWh per cubic metre when half the feed comes out as fresh water. The best reverse osmosis membranes now work within a factor of two of it, but whole plants, with their intakes, filters and pumps, use two to six times the floor. Desalination has to grow more than tenfold for everyone to have water, mostly on cheap solar power that comes by day, so every kilowatt-hour saved per cubic metre and every point of recovery counts.
The target
Seawater desalination that uses about 2 kWh per cubic metre for the whole plant, intake to tap, at 50 percent recovery or more, and that can follow the output of a solar field through the day, so that it can supply about a billion cubic metres a day by 2071.
What exists to build on
- Elimelech and Phillip put the least energy to desalinate 35 g per litre seawater at 50 percent recovery at 1.06 kWh per cubic metre, reported a pilot reverse osmosis stage running at 1.8 kWh, and found intake, pretreatment, post-treatment and discharge add more than 1 kWh. doi.org, 2011
- The IEA puts seawater reverse osmosis at about 2.5 to 6 kWh per cubic metre. iea.org, 2026
- Guinness World Records lists the Canary Islands Institute of Technology's DESALRO 2.0, a 2,500 cubic metre a day plant on Gran Canaria, at 1.794 kWh per cubic metre in February 2025. guinnessworldrecords.com, 2025
- In April 2026 the Saudi Water Authority reported 1.55 kWh per cubic metre from a 200,000 cubic metre a day reverse osmosis unit at Yanbu, without saying whether that covers intake and pretreatment. tradearabia.com, 2026
- Warsinger and colleagues at MIT modelled batch and closed-circuit reverse osmosis, which raise pressure as the brine strengthens, and predicted energy savings of up to 64 and 37 percent over continuous designs for brackish water at high recovery. dspace.mit.edu, 2016
- Wei, Lienhard and colleagues built a batch reverse osmosis prototype that matched their model within 2.7 percent, but salt left in the system between cycles cut the predicted saving for seawater at 50 percent recovery to 11 percent. dspace.mit.edu, 2020
- A University of Birmingham batch reverse osmosis rig on seawater at 65.5 percent recovery cut measured electrical energy from 3.82 to 3.42 kWh per cubic metre against continuous operation. pure-oai.bham.ac.uk, 2024
What is missing
The best membrane stages run at 1.55 to 1.8 kWh per cubic metre, but whole plants use 2.5 to 6, and the extra kilowatt-hour or more goes to intake, filtering and pumping, which membrane research rarely touches. Batch designs promised savings of a third or more; seawater rigs built so far point to 10 to 13 percent. Recovery is held near half: at 75 percent the brine's osmotic pressure would pass 100 bar, beyond what seawater membranes are built for, and scale grows on the membranes first. Plants are also built to run at steady flow around the clock, so they pay for batteries or grid power to use sunlight that comes for a third of the day.
What this project invents for it
How it connects
- It needs
- Terawatt solar factories
- It opens the way to
- Clean water for everyoneMinerals from the brine